Inquiry Email Whatsapp
CEEG Traction Rectifier Dry-Type Transformers Supplier 1000kVA 2000kVA 3000kVA
Brand: CEEG
Phase: Three Phase
Type: Dry-Type
Rated Capacity: 200kVA-4400kVA
Rated Voltage: 0.4kV-38.5kV
Nature of Business: Manufacturer
Contact Us
CEEG Traction Rectifier Dry-Type Transformers Supplier 1000kVA 2000kVA 3000kVA
Brand: CEEG
Phase: Three Phase
Type: Dry-Type
Rated Capacity: 200kVA-4400kVA
Rated Voltage: 0.4kV-38.5kV
Nature of Business: Manufacturer
Contact Us

CEEG Traction Rectifier Dry-Type Transformers Supplier 1000kVA 2000kVA 3000kVA-ezwj.jpg

Rectification is the general term for three operating modes: rectification, inversion, and frequency conversion, among which rectification is the most widely used. Most industrial rectified DC power supplies are generated by rectifier equipment consisting of rectifier transformers and rectifiers connected to the AC power grid. The most common application of rectifier transformers is in the electrochemical industry, where electrolysis of colored metal compounds is used to produce aluminum, magnesium, copper, and other metals; electrolysis of salt is used to produce chlor-alkali; and electrolysis of water is used to produce hydrogen and oxygen. With issues such as the depletion of fossil energy, the deteriorating ecological environment, and frequent extreme weather events, there has been explosive growth in the hydrogen energy industry. Hydrogen energy, as a rich and green low-carbon secondary energy source, is gradually becoming one of the important carriers of the global energy transition. With the requirements of carbon peak and carbon neutrality, the combination of hydrogen production rectification equipment and electrolysis water technology with renewable energy sources such as photovoltaics, wind power, or hydropower can produce high-purity hydrogen and oxygen, which will have wider applications in the global economy.

Product Performance Features:

1. Safety and reliability: The transformer is impregnated with non-toxic, flame-retardant epoxy resin, with high mechanical strength, difficult to ignite, fire-resistant, and pollution-free.

2. Convenient installation: Dry-type rectifier transformers are delivered as complete units and can be put into operation immediately upon installation, convenient and efficient.

3. High overload capacity: The insulation heat resistance level of the transformer is Class H, with a heat resistance temperature of up to 180°C. Maximum overload capacity reaches 200%.

4. Low noise: Noise is reduced by 3~5 decibels compared to national standards.

5. Investment saving: Dry-type rectifier transformers can be installed with other electrical equipment such as rectifiers, eliminating the need for separately designed distribution rooms, saving space, and reducing initial investment.

6. Diverse varieties: Complete product range covering special transformers in various fields such as rectifiers, electric furnaces, and frequency conversion transformers.

7. Customization: Flexibly designed according to specific customer requirements, with rapid response.

8. Authority certification: Certified by the National Electrical Products Quality Supervision and Inspection Center.

CEEG Traction Rectifier Dry-Type Transformers Supplier 1000kVA 2000kVA 3000kVA.jpgParameters.png

Technical Parameters

General Rectifier Dry-Type Transformers

Model

Capacity(KVA)

Rated Voltage(KV)

Tapping Range

Connection Section

Short Circuit Impedance

Efficiency

Weight(kg)

Net Side

Valve Side

ZBSCB10

200

10
6.3

0.4
0.66
0.69

2*2.5%

Dyn11
Yyn0
Dd0

4.0

≥0.97

1250

ZBSCB10

250

4.0

≥0.97

1430

ZBSCB10

315

4.0

≥0.97

1570

ZBSCB10

400

4.0

≥0.98

1750

ZBSCB10

500

4.0

≥0.98

1970

ZBSCB10

630

6.0

≥0.98

2250

ZBSCB10

800

6.0

≥0.98

2590

ZBSCB10

1000

6.0

≥0.98

2940

ZBSCB10

1250

6.0

≥0.98

3420

ZBSCB10

1600

6.0

≥0.98

3830

ZBSCB10

2000

6.0

≥0.99

4500

ZBSCB10

2500

6.0

≥0.99

5350

ZBSCB10

500

35
36
37
38.5

6.0

≥0.98

2680

ZBSCB10

630

6.0

≥0.98

3300

ZBSCB10

800

6.0

≥0.98

3810

ZBSCB10

1000

6.0

≥0.98

4650

ZBSCB10

1250

6.0

≥0.98

5250

ZBSCB10

1600

6.0

≥0.98

5750

ZBSCB10

2000

6.0

≥0.99

6380

ZBSCB10

2500

6.0

≥0.99

7390

Traction rectifier transformer

Model

Capacity(KVA)

Rated Voltage(KV)

Tapping Range

Connection Section

Short Circuit Impedance

Efficiency

Weight(kg)

Net Side

Valve Side

ZQSC-800/10

800

10
6.3

0.66
0.69
0.96
1.10
3.0

±2*2.5%

Dy11d0

6.0
7.0
8.0
10.5
12.5

≥0.96

3500

ZQSC-1000/10

1000

4330

ZQSC-1250/10

1250

4900

ZQSC-1600/10

1600

4300

ZQSC-1800/10

1800

5100

ZQSC-2000/10

2000

6000

ZQSC-2500/10

2500

6700

ZQSC-2750/10

2750

7100

ZQSC-3300/10

3300

8200

ZQSC-1600/35

1600

35
33

5900

ZQSC-2000/35

2000

6500

ZQSC-2500/35

2500

7500

ZQSC-2750/35

2750

8600

ZQSC-3000/35

3000

9100

ZQSC-3300/35

3300

9800

ZQSC-4000/35

4000

10800

ZQSC-4400/35

4400

11900

General Rectifier Dry-Type Transformers

Model

Capacity(KVA)

Rated Voltage(KV)

Tapping Range

Connection Section

Short Circuit Impedance

Efficiency

Weight(kg)

Net Side

Valve Side

ZBSCB10

200

10
6.3

0.4
0.66
0.69

2*2.5%

Dyn11
Yyn0
Dd0

4.0

≥0.97

1250

ZBSCB10

250

4.0

≥0.97

1430

ZBSCB10

315

4.0

≥0.97

1570

ZBSCB10

400

4.0

≥0.98

1750

ZBSCB10

500

4.0

≥0.98

1970

ZBSCB10

630

6.0

≥0.98

2250

ZBSCB10

800

6.0

≥0.98

2590

ZBSCB10

1000

6.0

≥0.98

2940

ZBSCB10

1250

6.0

≥0.98

3420

ZBSCB10

1600

6.0

≥0.98

3830

ZBSCB10

2000

6.0

≥0.99

4500

ZBSCB10

2500

6.0

≥0.99

5350

ZBSCB10

500

35
36
37
38.5

6.0

≥0.98

2680

ZBSCB10

630

6.0

≥0.98

3300

ZBSCB10

800

6.0

≥0.98

3810

ZBSCB10

1000

6.0

≥0.98

4650

ZBSCB10

1250

6.0

≥0.98

5250

ZBSCB10

1600

6.0

≥0.98

5750

ZBSCB10

2000

6.0

≥0.99

6380

ZBSCB10

2500

6.0

≥0.99

7390

Model

Capacity(KVA)

Rated Voltage(KV)

Tapping Range

Connection Section

Short Circuit Impedance

Efficiency

Weight(kg)

Net Side

Valve Side

ZQSC-800/10

800

10
6.3

0.66
0.69
0.96
1.10
3.0

±2*2.5%

Dy11d0

6.0
7.0
8.0
10.5
12.5

≥0.96

3500

ZQSC-1000/10

1000

4330

ZQSC-1250/10

1250

4900

ZQSC-1600/10

1600

4300

ZQSC-1800/10

1800

5100

ZQSC-2000/10

2000

6000

ZQSC-2500/10

2500

6700

ZQSC-2750/10

2750

7100

ZQSC-3300/10

3300

8200

ZQSC-1600/35

1600

35
33

5900

ZQSC-2000/35

2000

6500

ZQSC-2500/35

2500

7500

ZQSC-2750/35

2750

8600

ZQSC-3000/35

3000

9100

ZQSC-3300/35

3300

9800

ZQSC-4000/35

4000

10800

ZQSC-4400/35

4400

11900

CEEG Transformer Production Base covers an area of over 600 acres (40 hectares), with a total construction area of 180,000 square meters and a workforce of more than 1,200 workers. Equipped with a complete set of world-class transformer production and testing equipment including cutting, vacuum casting, vacuum impregnation, and testing, it has an annual production capacity of 30 million kVA of power transformers.

The factory possesses a comprehensive set of cutting-edge equipment representing industry-leading standards, including shearing machines, fully automatic winding machines, robotically operated automatic stacking machines, Germany's Hedrich vacuum casting tanks, vacuum impregnation equipment, air cushion transport vehicles, fully enclosed production workshops with a cleanliness level of 100,000, 20-ton vertical winding machines, 10-ton horizontal winding machines, kerosene gas-phase drying equipment, and 200-ton cranes. Additionally, it has pioneered the application of transformer collaborative design platforms in the industry, effectively integrating product data, product development, and production processes.

CEEG production ability (1).jpgCEEG certificates.jpg

REQUEST A QUOTE

CEEG will offer custom quotes and powerful solutions to meet your needs.
Send us your details and we'll get back to you as soon as possible.